01 Scope
Specifies minimum immunity for equipment in residential/commercial/light-industrial environments, referencing IEC 61000-4-x tests; default when no product standard applies.
03 Terms and definitions
Performance criteriaA/B/C by degree of functional preservation.
04 Technical requirements
ESD, RI, EFT, surge, conducted RF, dips per IEC 61000-4-x.
Residential/commercial/light-industrial.
As per each basic standard.
Disclaimer:This page is a technical summary of the corresponding standard for quick reference. All limits, clauses and methods are subject to the official publication and its latest amendments; formal compliance assessment must refer to the official issued text.