← Back to Standards Library
IEC 61000-4-5:2014
EMC - Testing and measurement techniques - Surge immunity test
📅 Issue date:—
🔄 Effective date:—
🌍 Type:International standard
01 Scope
Specifies surge (line-line ±1 kV, line-earth ±2 kV, 1.2/50 μs–8/20 μs) immunity test and criteria.
03 Terms and definitions
Performance criteriaA/B/C by degree of functional preservation.
04 Technical requirements
Line-line ±1 kV, line-earth ±2 kV (level 4).
1.2/50 μs voltage, 8/20 μs current.
Disclaimer:This page is a technical summary of the corresponding standard for quick reference. All limits, clauses and methods are subject to the official publication and its latest amendments; formal compliance assessment must refer to the official issued text.