← Back to Standards Library
CISPR 14-1:2020
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
📅 Issue date:2020
🔄 Effective date:2020
🌍 Type:国际标准
01 Scope
CISPR 14-1 specifies limits, measurement methods and operating conditions for electromagnetic emission (continuous/discontinuous disturbance, radiated disturbance) from 9 kHz to 400 GHz for household appliances, electric tools and similar apparatus. GB 4343.1-2024 is identically adopted from this standard.
02 Normative references
- CISPR 16-1-1 Measuring apparatus
- CISPR 16-1-2 Artificial mains network
- CISPR 16-2-1 Conducted disturbance measurements
- CISPR 16-2-3 Radiated disturbance measurements
- IEC 61000-3-2 Harmonic currents (if applicable)
03 Terms and definitions
Continuous disturbanceDisturbance on the measuring receiver without noticeable pauses.
Discontinuous disturbance (click)Disturbance produced intermittently, appearing as a series of distinct pulses.
Class A / Class B equipmentClass A for non-domestic environments; Class B for domestic use connected to the residential low-voltage mains (stricter limits).
04 Technical requirements
Mains terminals 150 kHz~30 MHz: Class B QP 66->56 (150k~500k), 56 (500k~5M), 60 (5M~30M) dBμV.
30 MHz~1 GHz: Class B 40 dBμV/m (3 m, 30~230M), 47 dBμV/m (3 m, 230M~1G).
30 MHz~300 MHz by absorption clamp: Class B 45->55 dBpW.
05 Test methods
EUT on non-conductive table or insulating support; antenna scanned over 1~4 m height.
Most unfavorable typical operating condition; tools loaded/locked-rotor as applicable.
06 Limits
Table 1 Mains-terminal conducted limits (Class B, dBμV)
| Frequency | QP | AV |
| 150 kHz ~ 500 kHz | 66 ~ 56 | 56 ~ 46 |
| 500 kHz ~ 5 MHz | 56 | 46 |
| 5 MHz ~ 30 MHz | 60 | 50 |
QP=quasi-peak, AV=average. Limits interpolated linearly with frequency.
Disclaimer:This page is a technical summary of the corresponding standard for quick reference. All limits, clauses and methods are subject to the official publication and its latest amendments; formal compliance assessment must refer to the official issued text.