← Back to Standards Library
CISPR 11-1 / GB 4824(发射)
Industrial, scientific and medical equipment - RF disturbance - Part 1: Emission limits
📅 Issue date:2015
🔄 Effective date:2015
🌍 Type:国际标准 / 国家标准 对应
01 Scope
CISPR 11-1 (the emission part of CISPR 11) specifies RF disturbance emission limits for ISM equipment and domestic RF appliances, managed by group (1/2) and class (A/B). GB 4824-2019 is modified-adopted.
02 Normative references
- CISPR 16-1-x / 16-2-x
- CISPR 11:2015
- GB 4824-2019
03 Terms and definitions
ISM equipmentIndustrial, scientific and medical RF equipment.
Group 1 / Group 2Group 1 unintentionally generates RF; Group 2 intentionally generates RF.
Class A / Class BClass A industrial; Class B domestic (stricter).
04 Technical requirements
Mains-terminal limits 150 kHz~30 MHz by group/class (Class B stricter).
Limits 30 MHz~1 GHz (and above) by group/class and distance.
Disclaimer:This page is a technical summary of the corresponding standard for quick reference. All limits, clauses and methods are subject to the official publication and its latest amendments; formal compliance assessment must refer to the official issued text.